Installation and Maintenance of Visual Warning Beacons

 

  • When installing a Hazard Warning Beacon care should be taken to position it in the most effective location to allow for all round light visibility and to maintain the IP(Ingress Protection) rating of the beacon. Therefore the following parameters should be noted:
  • To maintain the IP rating, the beacon should be mounted with the dome above the black moulded base. Never mount the unit with the dome horizontal or below base position.
  • Always fit mounting gasket provided (200/1 400/1 & 500/1 series models only) and ensure the 'O' ring is in place between the dome and base.
  • Fit a suitably IP rated cable gland (not supplied) where appropriate.
  • Regularly clean the beacon dome, as this will improve light output and help dissipate heat build up in the beacon. Do not clean dome with petroleum based cleaners.
  • Areas of vibration should be avoided. If this is not possible, then our Anti-Vibration mount must be used. Reference 50080 (available for 88/125 & 200/1 series models only).
  • Avoid situating Xenon beacons in close proximity to communication aerials or equipment and power lines that may be subject to high voltage transients.
  • DC voltage Xenon beacons should only be run on a smoothed rectified supply.
  • Unlike Incandescent lamps which fail instantly, Xenon tubes deteriorate very slowly. The impending failure of the tube will be indicated by erratic flashing. Once this is recognised the tubes should be replaced immediately. Failure to do so may result in damage to the electrical circuit.
  • Always disconnect the beacon from the supply before attempting maintenance. In addition, allow Xenon beacons at least 15 minutes to self-discharge before removing the dome as high voltages will remain on the pcb for this period of time

more information                                     

 

Back     


 

Moflash News

About Moflash

Home

Company Info

Distributors

Beacons & Signals

Products

Brands

Product Demo  

Contact Us

Contact

Ordering

Information

Info Zone

What's New

Shows & Events

Bespoke

Download Catalogue

 

Web site

Link to us

 

Latest News

Moflash News

↑ Grab this Headline Animator

All Product Links

 

    Subscribe in a reader

© Moflash Signalling Ltd 2009. All Rights Reserved

Creative Commons License
Some  content  of  this  site  is  licensed  under  a Creative Commons Licence.