Moflash Logo

 

 Home | Products | Bespoke | Product Demo | Distributors | Shows & Events | Company Info | Gallery | News | Catalogue | Contact Us

 

Explosion Proof Signals: Intrinsically Safe Products

APPLICATION: This IS range of Audible & Visual Signalling Devices is suited for use in potentially explosive atmospheres for Group I (Mining) & Group II (Above Ground) applications and typically suitable for Fire, Security, Process Control and general signalling installations.

 

IS-B Series

Intrinsically Safe Beacon

 

IS-S Series

Intrinsically Safe Electronic Sounder

 IS Beacon

 

Product Features

Approved by ATEX and IECEx

Zones 0, 1 and 2, 20, 21 and 22

9 High Output LED’s

Use with Galvanic Isolator or Zener barrier

Dustproof and Weatherproof to IP66

 

   UK Distribution

Export Distribution

 

 IS Sounder

 

Product Features

Approved by ATEX and IECEx

Zones 0, 1 and 2, 20, 21 and 22

Up to 105 dB(A) output

Use with Galvanic Isolator or Zener barrier

Dustproof and Weatherproof to IP66

 

   UK Distribution

Export Distribution

This LED Beacon has been approved for use in potentially explosive atmospheres for Group I (Mining) & Group II (Above Ground) applications and incorporates a high Ingress Protected IP66 enclosure.

 

This range is suitable for Fire, Security, Process Control and general signalling applications.

 

The beacon has a DIP switch that gives the options to change from a 1 Hz (60FPM) flash rate to a static (constantly On) signal.

 

A specially designed time saver base enables quick and easy installation of this unit with no extra cabling to be made to the head of the unit.

 

Connections are made to the base during the initial wiring phase which results in a faster more reliable installation. The beacon head simply twists & clicks into the pre-fixed base on commissioning avoiding any additional wiring & connections. Further details can be found on the installation sheet’

 

This unit must be used in conjunction with an approved Zener Barrier or Galvanic Isolator. See page 2 of the datasheet for further information & ordering details.

 

 

The IS electronic sounder has been approved for use in potentially explosive atmospheres for Group I (Mining) & Group II (Above Ground) applications and incorporates a high Ingress Protected IP66 enclosure.

 

This range is suitable for Fire, Security, Process Control and general signalling applications.

 

The sounder unit incorporates a Two stage alarm option and has a total of 32 selectable tones, selectable via a dip switch on the PCB and produces up to 105dB at 1 Meter.

 

A specially designed time saver base enables quick and easy installation of this unit with no extra cabling to be made to the head of the unit.

 

Connections are made to the base during the initial wiring phase which results in a faster more reliable installation. The sounder head simply twists & clicks into the pre-fixed base on commissioning avoiding any additional wiring & connections. Further details can be found on the installation sheet’.

 

This unit must be used in conjunction with an approved Zener Barrier or Galvanic Isolator. See page 2 of the datasheet for further information & ordering details.

 

 

 

 IS-SB Series

  Intrinsically Safe LED Sounder/Beacon

 

 MTL7700 Series

 Shunt-diode safety barriers

 IS Beacon

 

Product Features

Approved by ATEX and IECEx

Zones 0, 1 and 2, 20, 21 and 22

Combined Audible and Visual Signal

Use with Galvanic Isolator or Zener barrier

Dustproof and Weatherproof to IP66

 

   UK Distribution

Export Distribution

 

 No Image Available

 Product Features

 

For use in conventional fire detection

systems for protection within

hazardous areas

 

 Reverse polarity protection

 

 Simple installation onto standard DIN rail

 

 Removable colour-coded terminals

 

 For conductors up to 2.5 mm2

 

   

The IS-SB sounder/beacon has been approved for use in potentially explosive atmospheres for Group I (Mining) & Group II (Above Ground) applications and incorporates a high Ingress Protected IP66 enclosure.

 

This range is suitable for Fire, Security, Process Control and general signalling applications.

 

The sounder/beacon unit incorporates a two stage alarm option and has a total of 32 selectable tones, selectable via a dip switch on the PCB and produces up to 105dB at 1 Meter.

 

A specially designed time saver base enables quick and easy installation of this unit with no extra cabling to be made to the head of the unit.

 

Connections are made to the base during the initial wiring phase which results in a faster more reliable installation. The sounder head simply twists & clicks into the pre-fixed base on commissioning avoiding any additional wiring & connections. Further details can be found on the installation sheet’.

 

This unit must be used in conjunction with an approved Zener Barrier or Galvanic Isolator. See page 2 of the datasheet for further information & ordering details.

 

All MTL7700 Series barriers are based on the same simple principle. Each channel contains two stages of pulse-tested Zener or forward connected diodes and an ‘infallible’ terminating resistor. In the event of an electrical fault in the safe area, the diodes limit the voltage that can reach the hazardous area and the resistor limits the current. A fuse protects the diodes, and the two stages of voltage limitation ensure continued safety if either stage should fail. No active output current limiting circuits are employed. All models are certified ‘ia’ for all zones and ‘IIC’ for all explosive atmospheres (except MTL7707P+ and MTL7729P+, 'ia' 'IIB').

 

 

 Site Map | Privacy | Terms & Conditions | Contact Us

+44 (0) 121 446 5322